Key Features:

115 VAC - 60 Hz.
SINGLE PRIMARY

Part
Number

VA

Secondary (R.M.S.)

Dim. Ref.

VAC

Amps

165Z3
150
3.0 C.T.
50
H10
165X5
150
5.0 C.T.
30
H9
165V7
157.5
7.5 C.T.
21
H9
165V10
200
10.0 C.T.
20
H10
165U11
165
11.0 C.T.
15
H9
165S12
126
12.6 C.T.
10
H7
165V12
252
12.6 C.T.
20
H12
165S18
180
18.0 C.T.
10
H10
165U18
270
18.0 C.T.
15
H16
165V18
360
18.0 C.T.
20
H18
165T22
264
22.0 C.T.
12
H16
165V22
440
22.0 C.T.
20
H19
165P25
125
25.0 C.T.
5
H7
165S25
250
25.0 C.T.
10
H12
165P30
150
30.0 C.T.
5
H7
165S30
300
30.0 C.T.
10
H16
165P60
300
60.0 C.T.
5
H16
165N80
320
80.0 C.T.
4
H18

165 Series - Mechanical & Schematic Data (115 VAC - 60 Hz. Single Primary):

165 3-D Drawing

165 Schematic

Mtg. Style

Dimensions (Inches)

Mtg. Slot

A

B

C

D

E

F

H7
3
3.25
2.56
2.5
3.25
4
.22 x .56
H9
3.75
2.63
3.13
3.13
2.5
3.25
.22 x .56
H10
3.75
3.13
3.13
3.13
2.75
3.5
.22 x .56
H12
3.75
3.63
3.13
3.13
3.25
4
.22 x .56
H16
4.5
3.88
3.75
3.75
2.75
3.5
.28 x .56
H18
4.5
4.38
3.75
3.75
3.25
4
.28 x .56
H19
4.5
4.38
3.75
3.75
3.75
4.5
.28 x .56


Dual Primary (117/234 VAC - 50/60 Hz.)

NEW
Click here to enlarge
click to enlarge
NEW

Key Features:

117/234 VAC - 50/60 Hz.
DUAL PRIMARY - SINGLE SECONDARY

Part
Number

VA

Secondary (R.M.S.)

Data Sheet

Reader File

VAC

Amps

265X5
150
5.0 C.T.
30
PDF Download
215K
265U6
101
6.3 C.T.
16
PDF Download
226K
265V6
126
6.3 C.T.
20
PDF Download
226K
265X6
158
6.3 C.T.
25
PDF Download
226K
265U10
175
10 C.T.
17.5
PDF Download
224K


265 Series - Wiring & Schematic Data (117/234 VAC - 50/60 Hz. Dual Primary - Single Secondary):

Primary Wiring Data
(both primaries must be engerized):

117 VAC Input:
1) Connect - Black to Brown
2) Connect - White to Orange

234 VAC Input:
1) Connect - White to Brown
2) Connect - Input to Black and Orange



117/234 VAC - 50/60 Hz.
DUAL PRIMARY - DUAL SECONDARY

Part
Number

VA

Secondary VAC (R.M.S.)

Data Sheet

Reader File

Series Wired (C.T.)

Parallel Wired

265S24
240
24V @ 10A
12V @ 20A
PDF Download
246K
265U24
360
24V @ 15A
12V @ 30A
PDF Download
245K
265V24
480
24V @ 20A
12V @ 40A
PDF Download
246K
265J234250
234V @ 1.07A
117V @ 2.14A
PDF Download
240K
265K234
350
234V @ 1.5A
117V @ 3A
PDF Download
237K
265L234
450
234V @ 1.92A
117V @ 3.84A
PDF Download
245K


265 Series - Wiring & Schematic Data (117/234 VAC - 50/60 Hz. Dual Primary - Dual Secondary):

Primary Wiring Data
(both primaries
must be engerized):

117 VAC Input:
1) Connect - Black to Brown
2) Connect - White to Orange

234 VAC Input:
1) Connect - White to Brown
2) Connect - Input to Black and Orange

Secondary Wiring Data
(both secondaries must be
utilized for full ratings):

Series Output:
1) Connect - Blue to Gray
2) Output: Red and Yellow

Parallel Output:
1) Connect - Red to Gray
2) Connect - Blue to Yellow