ISOLATION
Plug - In - Step Down (115VAC
- 95VAC) |
Path:
Home > Transformer Index
> Line Index
> Isolation - Step Down - Plug In
Key Features:
- Primary 115VAC, 50/60 Hz., Secondary 95VAC.
- Provides
circuit isolation.
- Electrostatic shield between primary
& secondary.
- World wide applications, 50 or 60
Hz. operation, step down (115VAC to 95 VAC).
- Designed
mainly for Japanese equipment in North America.
- Perfect
for operating "Classic" equipment that can not tolerate todays higher
line voltages (ie..125 VAC input will produce a stress free 105 VAC output at
full load PLUS isolation and shielding).
- Standard
3-wire, grounded plug (can also be used with adaptors
for proper grounding).
- Input (primary) connected to
a 5 foot long cord and standard North American plug (NEMA 5-15P)
- Output
(secondary) connected to two standard - 3 wire grounded receptacles.
- Features
include ventilated black steel case, rocker lighted on-off switch & fuse protected
output.
- Indoor use only.
- Remember
- These units do NOT convert line frequency
115VAC
to 95VAC | Cat.
No. | Capacity
VA | # of Outlets
| Dimensions |
| A |
B | C
|
| 179C |
250 | 2 |
6 | 6.75 | 4.75 |
| 179D |
500 | 2 |
6 | 8.25 | 4.75 |
| 179E |
750 | 2 |
7 | 8.25 | 5.38 |
| 179F |
1000 | 2 |
7 | 9.75 | 5.38 |
| 179G |
1500 | 2 |
8.5 | 9 | 6.75 |
Mechanical
& Schematic Data:

| Downloads |
Catalog page(s) on JUST this series (245K) |
Exactly what you are looking for???
Link
to our stocking distributors - most have "on-line" pricing, stock check
and ordering!!! 
Order from your favorite distributor