Home
"Classic"
Plate & Filament
Enclosed Power Transformers
HomeProductsDistributorsTechnicalContact UsOther Options

Path: Home > Transformer Index > Power > "Classic" H.V. - Enclosed - Chassis Mount

278X Photo

Key Features:

Part No.

VA

Primary
A.C. High Voltage
Secondary
R.M.S.

Filament #1
(VAC)

Filament #2
(VAC)

Dim.
Ref.

VAC
Hz.
263AX
32
115
60
200V C.T. @ 115ma.
5V @ 2A
-
X2
269AX
40
115
60
250V C.T. @ 115ma.
6.3V @ 2A
-
X4
269BX
38
115
60
300V C.T. @ 86ma.
6.3V @ 2A
-
X4
263CX
116
115
60
360V C.T. @ 287ma.
5V C.T. @ 3A
-
X9
269EX
43
115
60
380V C.T. @ 71ma.
6.3V @ 2.5A
-
X5
269GX
48
115
60
450V C.T. @ 75ma.
6.3V @ 2.5A
-
X5
270X
41
115
60
480V C.T. @ 46ma.
5V @ 2A
6.3V @ 1.5A
X4
270AX
42
115
60
480V C.T. @ 58ma.
6.3V @ 2.5A
-
X4
269JX
50
115
60
500V C.T. @ 69ma.
6.3V @ 2.5A
-
X5
270CAX
65
117
50/60
500V C.T. @ 81ma.
5V @ 2A
6.3V @ 2.5A
X7A
270DAX
76
117
50/60
520V C.T. @ 104ma.
6.3V @ 3.5A
-
X7B
270DAZ
76
117
60
520V C.T. @ 104ma.
6.3V @ 3.5A
-
Z7
270BX
53
115
60
550V C.T. @ 57.5ma.
5V @ 2A
6.3V @ 2A
X6
270CX
59
115
60
550V C.T. @ 75ma.
6.3V @ 0.6A
6.3V @ 2.5A
X6
270DX
83
115
60
550V C.T. @ 104ma.
5V @ 2A
6.3V @ 3A
X7
270EX
118
115
60
550V C.T. @ 144ma.
5V @ 3A
6.3V @ 4A
X9
270FX
138
115
60
550V C.T. @ 173ma.
5V @ 3A
6.3V C.T. @ 5A
X10
270HX
176
115
60
550V C.T. @ 230ma.
5V C.T. @ 3A
6.3V C.T. @ 6A
X19
271X
63
115
60
560V C.T. @ 69ma.
5V @ 2A
6.3V C.T. @ 2A
X6
272BX
95
115
60
600V C.T. @ 115ma.
5V @ 2A
6.3V @ 3A
X8
272DX
123
115
60
600V C.T. @ 144ma.
5V @ 3A
6.3V @ 4A
X9
272FX
146
115
60
600V C.T. @ 172ma.
5V C.T. @ 3A
6.3V C.T. @ 5A
X10
272HX
186
115
60
600V C.T. @ 230ma.
5V C.T. @ 3A
6.3V C.T. @ 6A
X19
272JX
236
115
60
600V C.T. @ 287ma.
5V C.T. @ 4A
6.3V C.T. @ 8A
X13
272X
74
115
60
620V C.T. @ 80ma.
5V @ 2A
6.3V @ 2.4A
X7
276X
150
115
60
640V C.T. @ 172ma.
5V C.T. @ 3A
6.3V C.T. @ 5A
X10
273AZ
49
117
50/60
650V C.T. @ 46ma.
5V @ 2A
6.3V @ 2A
Z6
273CZ
159
117
50/60
650V C.T. @ 172ma.
5V @ 3A
6.3V C.T. @ 5A
Z9
273DX
101
117
50/60
700V C.T. @ 103ma.
5V @ 2A
6.3V C.T. @ 3A
X9A
273DZ
101
117
50/60
700V C.T. @ 103ma.
5V @ 2A
6.3V C.T. @ 3A
Z8
273X
120
115
60
700V C.T. @ 126ma.
5V @ 2A
6.3V C.T. @ 4A
X9
273BX
182
115
60
700V C.T. @ 201ma.
5V @ 3A
6.3V C.T. @ 5A
X19
274AX
137
117
50/60
720V C.T. @ 138ma.
5V @ 3A
6.3V C.T. @ 3.5A
X10A
274X
138
115
60
750V C.T. @ 126ma.
5V @ 3A
6.3V C.T. @ 5A
X10
274BX
198
115
60
750V C.T. @ 201ma.
5V C.T. @ 3A
6.3V C.T. @ 6A
X19
275X
167
115
60
800V C.T. @ 155ma.
5V C.T. @ 3A
6.3V C.T. @ 5A
X11
278X
229
115
60
800V C.T. @ 230ma.
5V C.T. @ 3A
6.3V C.T. @ 6A
X19
278CX
454
115
60
800V C.T. @ 535ma.
6.3V C.T. @ 6A
-
X15
279X
186
115
60
850V C.T. @ 172ma.
5V @ 3A
6.3V C.T. @ 5A
X19
282X
273
115
60
1,000V C.T. @ 230ma.
5V C.T. @ 3A
6.3V C.T. @ 6A
X14 

Note: See our PDF Design Guide for rectifier use suggestions.

Mechanical & Schematic Data:

Vertical Mount ("X" mounting)

"X" Mount Drawing

Xfmr Schematic

* NOTE: Filament #1 and #2 windings may not exist or do not have C.T. connections - refer to table above.


Mtg. Style

Dimensions (Inches)

G-Mtg. Slot

A

B

C

D

E

X2
1.88
2.44
2.5
1.5
1.56
.19 x .31
X4
2.19
2.5
2.63
1.75
1.44
.19 x .25
X5
2.19
2.63
2.63
1.75
1.56
.19 x .25
X6
2.5
2.75
3.06
2
1.69
.203 x .38
X7
2.5
3
3.06
2
1.94
.203 x .38
X7A
2.5
3
3.13
2
2.06
.203 x .38
X7B
2.5
3
3.13
2
2.19
.203 x .38
X8
2.5
3.25
3.06
2
2.19
.203 x .38
X9
2.5
3.75
3.06
2
2.69
.203 x .38
X9A
2.88
3.5
3.5
2.25
2.44
.203 x .38
X9B
3.13
3.5
3.5
2.5
2.38
.203 x .38
X10
3.13
3.5
3.81
2.5
2.19
.203 x .38
X10A
3.13
3.5
3.88
2.5
2.38
.203 x .38
X11
3.13
3.75
3.81
2.5
2.44
.203 x .38
X13
3.75
4
4.56
3
2.81
.203 x .38
X14
3.75
4.5
4.56
3
3.31
.203 x .38
X15
3.75
5
4.56
3
3.81
.203 x .38
X19
3.13
4
3.81
2.5
2.69
.203 x .38


Horizontal Mount ("Z" mounting)

Click Here To Enlarge
(click to enlarge)

 

Xfmr Schematic

* NOTE: Filament #1 and #2 windings may not exist or do not have C.T. connections - refer to table above.


Mtg.
Style
Dimensions (Inches)
A
B
C
D
F
G
H
J
Z6
2.00
2.50
2.50
1.75
2.00
1.06
3.00
2.50
Z7
2.25
2.88
3.25
1.88
2.38
1.25
3.38
2.81
Z8
2.25
2.81
3.63
1.75
2.25
1.50
3.38
2.81
Z9
2.50
3.13
3.81
2.00
2.69
1.33
3.75
3.13


NOTE - Running Change to Primary Winding:

NEW Primary Connections

Due to customer suggestions we have added additional windings and a tap to our "200" series primaries. This will affect all production after August 2009. For those customers who need the 115V input - nothing has changed - simply use the White & Gray wires and tape the Black wire (see above schematic).

For those customers who are seeing too high a secondary voltage due to higher primary line voltages - use the White & Black wire and tape the gray wire (see above schematic).



Downloads
PDF Download Catalog page(s) on JUST this series (346K)



Exactly what you are looking for???
Link to our stocking distributors - most have "on-line" pricing, stock check and ordering!!!

Our Distributors
Order from your favorite distributor



Check out our "Classic" Product Distributors,
they specialize in this product...



Home | Products | Distributors | Technical | Contact Us | Other Options

Copyright; © 1998-2009 Hammond Mfg Co Inc
URL: http://www.hammondmfg.com